  diesel generator set mtu 4r0113 ds40 40 kwe / 60 hz / standby 208 - 600v reference mtu 4r0113 ds40 (40 kwe) for prime rating technical data system ratings standby voltage (l-l) 240v** 208v** 240v** 380v** 480v** 600v** phase 1 3 3 3 3 3 pf 1 0.8 0.8 0.8 0.8 0.8 hz 60 60 60 60 60 60 kw 40 40 40 40 40 40 kva 40 50 50 50 50 50 amps 166 138 120 76 60 48 skva@30% voltage dip 63 129 129 112 172 92 generator model 361csl1601 361csl1601 361csl1601 361csl1601 361csl1601 361psl1632 temp rise 130 c/40 c 130 c/40 c 130 c/40 c 130 c/40 c 130 c/40 c 130 c/40 c connection 12 lead 12 lead wye 12 lead delta 12 lead wye 12 lead wye 4 lead wye double delta ** ul 2200 o ? ered // ? emissions ? epa tier 3 certi ed // ? generator set is designed and manufactured in facilities certi ed to standards iso 9001:2008 and iso 14001:2004 // ? seismic certification ? optional ? ibc certi cation // ? ul 2200 / csa ? optional ? ul 2200 listed ? csa certi ed // ? performance assurance certification (pac) - generator set tested to iso 8528-5 for transient response - veri ed product design, quality and performance integrity - all engine systems are prototype and factory tested // ? power rating - accepts rated load in one step per nfpa 110 certifications and standards
2 // / ? / mtu 4r0113 ds40 (40 kwe) - standby // ? engine air cleaner oil pump oil drain extension and s/o valve full flow oil filter fuel filter with water separator jacket water pump thermostat blower fan and fan drive radiator - unit mounted electric starting motor - 12v governor ? mechanical droop base - formed steel sae flywheel and bell housing charging alternator - 12v battery box and cables flexible fuel connectors flexible exhaust connection epa certi ed engine // ? generator nema mg1, ieee and ansi standards compliance for temperature rise and motor starting self-ventilated and drip-proof superior voltage waveform solid state, volts-per-hertz regulator 1% voltage regulation no load to full load brushless alternator with brushless pilot exciter 4 pole, rotating field 130 c max. standby temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing 100% of rated load - one step 5% max. total harmonic distortion // ? digital control panel(s) digital metering engine parameters generator protection functions engine protection windows ? -based software multilingual capability remote communications to rdp-110 remote annunciator programmable input and output contacts ul recognized, csa certi ed, ce approved event recording ip 54 front panel rating with integrated gasket nfpa110 compatible standard equipment* // ? mtu onsite energy is a single source supplier // ? global product support // ? 2 year standard warranty // ? 4045tf280 diesel engine - 4.5 liter displacement - mechanical injection pump - 4-cycle // ? engine-generator resilient mounted // ? complete range of accessories // ? generator - brushless, rotating field generator - 2/3 pitch windings - 300% short circuit capability with optional permanent magnet generator (pmg) // ? digital control panel(s) - ul recognized, csa certi ed, nfpa 110 - complete system metering - lcd display // ? cooling system - integral set-mounted - engine-driven fan standard features* * represents standard product only. consult factory/mtu onsite energy distributor for additional con gurations.
3 // / ? / mtu 4r0113 ds40 (40 kwe) - standby // ? engine manufacturer john deere model 4045tf280 type 4-cycle arrangement 4-inline displacement: l (in 3 ) 4.5 (275) bore: cm (in) 10.6 (4.19) stroke: cm (in) 12.7 (5) compression ratio 19.0:1 rated rpm 1,800 engine governor mechanical droop max. power: kwm (bhp) 63 (85) speed regulation 0.5% air cleaner dry // ? liquid capacity (lubrication) total oil system: l (gal) 13 (3.4) engine jacket water capacity: l (gal) 8.5 (2.3) system coolant capacity: l (gal) 18.9 (5) // ? electrical electric volts dc 12 cold cranking amps under -17.8 c (0 f) 925 // ? fuel system fuel supply connection size 3/8? npt fuel return connection size 3/8? npt max. fuel lift: m (ft) 1.8 (6) recommended fuel diesel #2 total fuel flow: l/hr (gal/hr) 62.5 (16.5) // ? fuel consumption at 100% of power rating: l/hr (gal/hr) 17.4 (4.6) at 75% of power rating: l/hr (gal/hr) 13.6 (3.6) at 50% of power rating: l/hr (gal/hr) 9.5 (2.5) // ? cooling - radiator system ambient capacity of radiator: c ( f) 50 (122) max. restriction of cooling air: intake and discharge side of rad.: kpa (in. h 2 0) 0.12 (0.5) water pump capacity: l/min (gpm) 144 (38) heat rejection to coolant: kw (btum) 36 (2,049) heat radiated to ambient: kw (btum) 6.8 (384) fan power: kw (hp) 1.6 (2.2) // ? air requirements aspirating: *m 3 / min (scfm) 5.3 (187) air flow required for rad. cooled unit: *m 3 / min (scfm) 117 (4,088) remote cooled applications; air flow required for dissipation of radiated generator set heat for a max. of 25 f rise: *m 3 / min (scfm) 25 (867) * air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 ) // ? exhaust system gas temp. (stack): c (f) 579 (1,074) gas volume at stack temp: m 3 / min (cfm) 19.2 (679) max. allowable back pressure: kpa (in. h 2 0) 7.5 (30) min. allowable back pressure: kpa (in. h 2 0) n/a application data
4 // / ? / mtu 4r0113 ds40 (40 kwe) - standby ? mtu onsite energy. subject to alteration due to technological advances. oe 23 458 (77 3e) 2015-10 emissions data no x + nmhc co pm 3.8 0.69 0.22 all units are in g/hp-hr and shown at 100% load (not comparable to epa weighted cycle values). emission levels of the engine may vary with ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. the data was obtained in compliance with us epa regulations. the weighted cycle value (not shown) from each engine is guaranteed to be within the us epa standards. 5-mode emission data per 40 cfr 89 or 40 cfr 1039 (as applicable) is available upon request. rating definitions and conditions // ? standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 3046-1, bs 5514, and as 2789. average load factor: 85%. // ? deration factor: altitude : consult your local mtu onsite energy power generation distributor for altitude derations. temperature : consult your local mtu onsite energy power generation distributor for temperature derations. weights and dimensions sound data unit type standby full load level 0: open power unit db(a) 80.5 sound data is provided at 7 m (23 ft). generator set tested in accordance with iso 8528-10 and with in nite exhaust. system dimensions (l x w x h) weight (dry/less tank) open power unit (opu) 1,781 x 800 x 1,321 mm (70.13 x 31.5 x 52 in) 872 kg (1,920 lb) drawing above for illustration purposes only, based on standard open power 480 volt generator set. lengths may vary with other voltages. do not use for installation design. see website for unit speci c template drawings. weights and dimensions are based on open power units and are estimates only. consult the factory for accurate weights and dimen sions for your speci c generator set. c/f = consult factory/mtu onsite energy distributor n/ a = not available mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com


▲Up To Search▲   

 
Price & Availability of MTU4R0113DS40

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X